The structural-geometric and functional parameters of the heart in patients after mitral prosthetics with new full-flow valves in the long-term period
- Authors: Perekopskaya V.S.1,2, Morova N.A.1, Tsekhanovich V.N.1,2
-
Affiliations:
- Omsk State Medical University
- Regional Clinical Hospital
- Issue: Vol 13, No 1 (2022)
- Pages: 4-10
- Section: Original study articles
- URL: https://cardiosomatics.ru/2221-7185/article/view/83336
- DOI: https://doi.org/10.17816/22217185.2022.1.201469
- ID: 83336
Cite item
Full Text
Abstract
Aim. To compare the results of mitral valve replacement with the full-flow mechanical valve «MedInzh-ST» and the classical prosthesis «MedInzh-2», to learn the structural and functional parameters of the heart depending from the prosthesis in the long-tern period.
Material and methods. From 2015 to February 2020 years an the basis of the cardio-surgical department of the «Regional clinical Hospital» 116 patients, in order to correct defects, were underwent mitral prosthetics with «MedInzh» valves. Of these 55 patients received a new full-flow valve «MedInzh-ST». 61 patients – a classical «MedInzh-2». Before surgery and in the long-term period all patients were underwent transthoracic echocardiography with using expert-class devices. In the long-tern postoperative period 34 patients were underwent echocardiographic research after implantation full-flow valves and 40 patients after prosthetics of classical prosthesis.
Results. The choice of the prosthesis model did not affect the incidence of postoperative complications and the rate of hospital mortality. In all cause of death is not associated with impaired function of the prosthesis. All patients before the discharge from hospital were fixed the positive effect from surgical treatment. In the long-term postoperative period between patients after implantation of full-flow valves, the cases of prosthetic platelets were not registered. One patient was diagnosed with prosthetic thrombosis after implantation of a classical prosthesis, which required further reprosthetics. There were no signs of prosthetic endocarditis and paraprosthetic fistula in both groups. There were no significant differences in the structural and geometric parameters of the heart in all patients.
Conclusion. Analysis of the functional characteristics of the new full-flow valve «MedInzh-ST» in the long-term period allows us to conclude that the new valve model meets modern requirements for efficiency and safety.
Full Text
СПИСОК СОКРАЩЕНИЙ
ИК – искусственный клапан
КДО – конечный диастолический объем
КДР – конечный диастолический размер
КСО – конечный систолический объем
КСР – конечный систолический размер
ОНМК – острое нарушение мозгового кровообращения
ТМГД – трансмитральный градиент давления
Р ЛА – давление в легочной артерии
Введение
Пороки клапанов сердца составляют от 7 до 10% всех заболеваний сердца. Наиболее часто встречается поражение митрального клапана. Причинами митральных пороков являются дегенеративные изменения, ревматическая болезнь сердца, инфекционный эндокардит, дисплазия соединительной ткани сердца [1].
По данным хирургических регистров, в мире ежегодно имплантируется от 250 тыс. до 280 тыс. клапанных протезов сердца. Несмотря на очевидный прогресс в хирургии сердца, совершенствование реконструктивно-пластических или эндоваскулярных транскатетерных операций, число имплантаций искусственных клапанов (ИК) не снижается. Протезирование клапанов сердца остается эффективным и часто единственно возможным способом коррекции пороков, позволяющим устранить патологические изменения, улучшить внутрисердечную гемодинамику и качество жизни пациентов [2, 3].
В настоящее время не существует идеальной модели ИК сердца. Сегодня приоритетным направлением в создании ИК сердца является разработка протезов с максимально возможным эффективным отверстием для обеспечения гемодинамики, приближенной к нативному клапану.
Новой усовершенствованной моделью ИК является отечественный полнопроточный двустворчатый клапан «МедИнж-СТ». Главным преимуществом данного протеза является его конструкция: створки фиксированы на шарнирных креплениях, находящихся на противоположных сторонах кольца, что способствует устранению застойных зон вокруг креплений и снижает вероятность развития тромботических осложнений. Запирающий элемент, выполненный в виде двух цилиндрических сегментов, обеспечивает централизацию потока крови, минимальную травматизацию форменных элементов, увеличение эффективной площади отверстия клапана и уменьшение транспротезного градиента давления. Прочность клапана «МедИнж-СТ» обусловлена исходной высокой прочностью монолитного изотропного пиролитического углерода [2, 4].
Цель исследования – сравнить результаты протезирования митрального клапана полнопроточными механическими протезами «МедИнж-СТ» и классическими протезами «МедИнж-2», изучить структурно-геометрические и функциональные параметры сердца в зависимости от модели протеза в отдаленном периоде.
Материал и методы
С 2015 по февраль 2020 г. на базе кардиохирургического отделения БУЗОО «Областная клиническая больница» 116 пациентам с целью коррекции пороков было выполнено митральное протезирование клапанами «МедИнж». До включения в исследование от всех участников было получено письменное информированное согласие. В исследование включены все пациенты, перенесшие коррекцию митрального порока механическими протезами «МедИнж». Пациентов с ишемической болезнью сердца и перенесенным инфарктом миокарда в исследование не включали. Операция выполнена по стандартной методике в условиях искусственного кровообращения, нормотермии.
Условий и показаний для имплантации той или иной модели протеза для определенных групп пациентов не было, выбор модели клапана зависел от материально-технического обеспечения. Новый полнопроточный протез «МедИнж-СТ» имплантирован 55 пациентам (группа 1), классический «МедИнж-2» – 61 пациенту (группа 2). В группе 1 преобладали пациенты мужского пола, в группе 2 – женского. Средний возраст пациентов составил 57 (50; 62) и 55 (50; 62) лет соответственно.
В отдаленном послеоперационном периоде эхокардиографическое исследование выполнено 34 пациентам после имплантации полнопроточных клапанов и 40 пациентам – после протезирования классическими протезами. Средняя продолжительность наблюдения в группе 1 составила 2,8 [1; 3] года, в группе 2 – 3,1 [2; 3, 5] года. Данный период наблюдения является достаточным для оценки процессов ремоделирования сердца после операции и выявления поздних клапанзависимых послеоперационных осложнений.
Всем пациентам перед операцией и в отдаленном периоде выполняли трансторакальную эхокардиографию с использованием аппаратов экспертного класса Vivid E9, GE Vivid Q General Electric (США). Определяли следующие параметры: конечный диастолический размер (КДР), конечный систолический размер (КСР), конечный диастолический объем (КДО), конечный систолический объем (КСО), фракцию выброса левого желудочка, размер левого предсердия, пиковый и средний трансмитральные градиенты давления (ТМГД), степень митральной регургитации, размер правого желудочка, систолическое давление в легочной артерии (Р ЛА). Существенных различий дооперационных эхокардиографических показателей среди лиц, перенесших протезирование клапанами разных моделей, не было.
Статистические методы. Для обработки информации использовались программы Statistica 12, Microsoft Excel. Вид распределения вариационных рядов оценивался при помощи критерия Шапиро–Уилка. Вид распределения отличался от нормального, в связи с чем анализ проводили с помощью непараметрических методов. Для описания количественных данных рассчитывались медиана (Me) и процентили (Р25, Р75), для качественных данных – доли. Сравнение количественных данных двух независимых выборок осуществлялось при помощи U-критерия Манна–Уитни, двух зависимых выборок – критерия Уилкоксона. Для анализа различия частот в двух независимых группах использовался критерий χ2 с поправкой Йейтса. Статистическая значимость присваивалась при значении p<0,05.
Результаты
Причинами пороков сердца были ревматическая болезнь сердца, инфекционный эндокардит, дисплазия соединительной ткани сердца, в том числе миксоматозная дегенерация. Для определения влияния модели протеза на послеоперационные показатели пациенты каждой группы были разделены на подгруппы в зависимости от вида порока: преобладание стеноза или недостаточности. В группе 1 митральный стеноз преобладал у 12 пациентов (группа 1.1), в группе 2 – у 16 пациентов (группа 2.1). Митральная недостаточность преобладала у 43 пациентов группы 1 (группа 2.1), у 45 пациентов группы 2 (группа 2.2). Все пациенты были сопоставимы по клиническим и эхокардиографическим характеристикам (табл. 1, 2).
Таблица 1. Дооперационные эхокардиографические параметры у пациентов обеих групп
Table 1. Preoperative echocardiographic parameters in patients of both groups
Параметр | Группа 1.1 (n=12) | Группа 2.1 (n=16) | р1.1–2.1 | Группа 1.2 (n=43) | Группа 2.2 (n=45) | р1.2–2.2 |
КДО, мл | 106 [98; 124] | 95 [91; 114] | 0,186 | 153 [147; 161] | 150 [144; 159] | 0,740 |
КСО, мл | 38 [31; 42] | 41 [38; 54] | 0,821 | 57 [50; 62] | 60 [55; 67] | 0,864 |
КДР, см | 0,746 | 0,896 | ||||
КСР, см | 0,687 | 0,862 | ||||
ФВ, % | 63 [55; 68] | 61 [56; 70] | 0,673 | 64 [57; 69] | 62 [58; 72] | 0,716 |
ЛП, см | 0,098 | 0,520 | ||||
пикТМГД, мм рт. ст. | 25 [18; 28] | 27 [22; 31] | 0,616 | 7 [5; 8] | 8 [4; 10] | 0,614 |
срТМГД, мм рт. ст. | 14 [12; 18] | 14 [11; 18] | 0,842 | 0,738 | ||
Степень регургитации | 0,549 | 3 [3; 4] | 3 [3; 4] | 0,898 | ||
ПЖ, см | 0,087 | 0,765 | ||||
Р ЛА, мм рт. ст. | 67 [62; 71] | 57 [54; 63] | 0,404 | 45 [38; 51] | 55 [46; 60] | 0,343 |
Примечание. Здесь и в табл. 3–6: ФВ ЛЖ – фракция выброса левого желудочка, ЛП – размер левого предсердия, пикТМГД – пиковый трансмитральный градиент давления, срТМГД – средний трансмитральный градиент давления, ПЖ – правый желудочек.
Таблица 2. Клиническая характеристика пациентов
Table 2. Clinical characteristics of patients
Параметр | Группа 1 (n=55) | Группа 2 (n=61) | р |
Мужской пол, абс. (%) | 32 (58) | 22 (36) | 0,028 |
Возраст, лет, Ме (Р25; Р75) | 57 (50; 62) | 55 (50; 62) | 0,832 |
ИМТ, кг/м2, Ме (Р25; Р75) | 27,4 (23,1; 30,9) | 27,6 (24,5; 32,2) | 0,817 |
Избыточная масса тела, абс. (%) | 18 (33) | 15 (25) | 0,445 |
Ожирение, абс. (%) | 16 (29) | 17 (28) | 0,952 |
Гипертоническая болезнь, абс. (%) | 28 (51) | 30 (49) | 0,853 |
Сахарный диабет, абс. (%) | 6 (11) | 4 (7) | 0,616 |
ХОБЛ, абс. (%) | 19 (35) | 11 (18) | 0,070 |
Фибрилляция предсердий, абс. (%) | 20 (36) | 23 (38) | 0,966 |
Давность ухудшения, месяцев, Ме (Р25; Р75) | 8 (6; 14) | 6 (3; 12) | 0,656 |
НК по NYHA, Ме (Р25; Р75) | 3 (2,5; 3) | 3 (2,7; 3) | 0,846 |
Ревматическая болезнь сердца, абс. (%) | 15 (27) | 21 (34) | 0,529 |
Миксоматозная дегенерация без отрыва хорд, абс. (%) | 12 (22) | 8 (13) | 0,321 |
ИЭ без отрыва хорд, абс. (%) | 4 (7) | 8 (13) | 0,468 |
ДСТ без отрыва хорд, абс. (%) | 4 (7) | 6 (10) | 0,873 |
Отрыв хорд, абс. (%) | 19 (35) | 18 (30) | 0,703 |
Тромбоз протеза, абс. (%) | 1 (2) | 0 | 0,431 |
Преобладание стеноза, абс. (%) | 12 (22) | 16 (26) | 0,737 |
Преобладание недостаточности, абс. (%) | 43 (78) | 45 (74) | 0,737 |
Повторное протезирование, абс. (%) | 2 (4) | 4 (7) | 0,773 |
Примечание. ДСТ – дисплазия соединительной ткани, ИМТ – индекс массы тела, ИЭ – инфекционный эндокардит, НК по NYHA – недостаточность кровообращения по NYHA, ХОБЛ – хроническая обструктивная болезнь легких.
Интраоперационная летальность в обеих группах не зарегистрирована.
За время стационарного лечения в группе 1 зарегистрирован один случай тромбоза протеза у пациентки с доказанной тромбофилией, в группе 2 случаев тромбоза протеза не было. У пациентов после протезирования полнопроточными клапанами зарегистрирован 1 случай транзиторной ишемической атаки, в группе классических протезов – 2 случая острого нарушения мозгового кровообращения (ОНМК) по ишемическому типу, один случай летального ОНМК по геморрагическому типу с образованием внутримозговой гематомы.
В 30-дневный период после операции в группе полнопроточных протезов зафиксировано 2 (3,6%) случая летального исхода, в группе классических протезов – 5 (8,2%) случаев (р=0,523). Во всех случаях смерть не была связана с нарушением функции протеза.
Результаты эхокардиографического исследования перед выпиской подтверждают эффективность оперативного лечения в обеих группах (табл. 3, 4). Нарушений в работе протеза не зарегистрировано.
Таблица 3. Послеоперационные эхокардиографические параметры у пациентов группы 1
Table 3. Postoperative echocardiographic parameters in group 1 patients
Параметр | Стеноз | Недостаточность | р1–2; 3–4 | ||
до операции (1) (n=12) | после операции (2) (n=12) | до операции (3) (n=43) | после операции (4) (n=41) | ||
КДО, мл | 106 [98; 124] | 124 [112; 135] | 153 [147; 161] | 117 [110;125] | 0,364; 0,036 |
КСО, мл | 38 [31; 42] | 55 [49; 64] | 57 [50; 62] | 45 [40; 49] | 0,085; 0,028 |
КДР, см | 0,246; 0,042 | ||||
КСР, см | 0,482; 0,034 | ||||
ФВ ЛЖ, % | 63 [55; 68] | 58 [55; 60] | 64 [57; 69] | 60 [57; 64] | 0,670; 0,267 |
ЛП, см | 0,095; 0,040 | ||||
пикТМГД, мм рт. ст. | 25 [18; 28] | 13 [11; 15] | 7 [5; 8] | 9 [7; 12] | 0,028; 0,568 |
срТМГД, мм рт. ст. | 14 [12; 18] | 5 [4; 8] | 5 [4; 7] | 0,009; 0,612 | |
Степень регургитации | 3 [3; 4] | 0,043; 0,033 | |||
ПЖ, см | 0,045; 0,864 | ||||
Р ЛА, мм рт. ст. | 67 [62; 71] | 48 [45; 54] | 45 [38; 51] | 31 [28; 37] | 0,027; 0,038 |
Таблица 4. Послеоперационные эхокардиографические параметры у пациентов группы 2
Table 4. Postoperative echocardiographic parameters in group 2 patients
Параметр | Стеноз | Недостаточность | р1–2; 3–4 | ||
до операции (1) (n=16) | после операции (2) (n=14) | до операции (3) (n=45) | после операции (4) (n=42) | ||
КДО, мл | 95 [91; 114] | 107 [98; 114] | 150 [144; 159] | 131 [122; 140] | 0,504; 0,028 |
КСО, мл | 41 [38; 54] | 44 [39; 52] | 60 [55; 67] | 54 [49; 57] | 0,412; 0,030 |
КДР, см | 0,798; 0,041 | ||||
КСР, см | 0,784; 0,562 | ||||
ФВ, % | 61 [56; 70] | 58 [54; 60] | 62 [58; 72] | 59 [53; 62] | 0,435; 0,238 |
ЛП, см | 0,187; 0,034 | ||||
пикТМГД, мм рт. ст. | 27 [22; 31] | 13 [10; 14] | 8 [4; 10] | 11 [9; 14] | 0,008; 0,095 |
срТМГД, мм рт. ст. | 14 [11; 18] | 6 [4; 8] | 5 [4; 10] | 0,012; 0,180 | |
Степень регургитации | 3 [3; 4] | 0,403; 0,019 | |||
ПЖ, см | 0,346; 0,204 | ||||
Р ЛА, мм рт. ст. | 57 [54; 63] | 38 [32; 43] | 55 [46; 60] | 34 [30; 42] | 0,036; 0,012 |
Эхокардиографические параметры сердца перед выпиской были сопоставимы у пациентов вне зависимости от имплантируемой модели протеза (табл. 5).
Таблица 5. Послеоперационные эхокардиографические параметры у пациентов обеих групп
Table 5. Postoperative echocardiographic parameters in patients of both groups
Параметр | Группа 1.1 (n=12) | Группа 2.1 (n=14) | р1.1–2.1 | Группа 1.2 (n=41) | Группа 2.2 (n=42) | р1.2–2.2 |
КДО, мл | 106 [98; 124] | 95 [91; 114] | 0,186 | 153 [147; 161] | 150 [144; 159] | 0,740 |
КСО, мл | 38 [31; 42] | 41 [38; 54] | 0,821 | 57 [50; 62] | 60 [55; 67] | 0,864 |
КДР, см | 0,746 | 0,896 | ||||
КСР, см | 0,687 | 0,862 | ||||
ФВ, % | 63 [55; 68] | 61 [56; 70] | 0,673 | 64 [57; 69] | 62 [58; 72] | 0,716 |
ЛП, см | 0,098 | 0,520 | ||||
пикТМГД, мм рт. ст. | 25 [18; 28] | 27 [22; 31] | 0,616 | 7 [5; 8] | 8 [4; 10] | 0,614 |
срТМГД, мм рт. ст. | 14 [12; 18] | 14 [11; 18] | 0,842 | 0,738 | ||
Степень регургитации | 0,549 | 3 [3; 4] | 3 [3; 4] | 0,898 | ||
ПЖ, см | 0,087 | 0,765 | ||||
Р ЛА, мм рт. ст. | 67 [62; 71] | 57 [54; 63] | 0,404 | 45 [38; 51] | 55 [46; 60] | 0,343 |
В отдаленном периоде среди пациентов после имплантации полнопроточными клапанами случаев тромбоза протеза не зарегистрировано. У 1 пациентки после имплантации классического протеза выявлен тромбоз протеза, потребовавший в дальнейшем репротезирования. При этом все пациенты имели уровень МНО в терапевтическом диапазоне. В обеих группах признаков протезного эндокардита и парапротезной фистулы не выявлено. Значимых различий структурно-геометрических показателей сердца у всех исследуемых выявлено не было (табл. 6). Средний транспротезный градиент давления в обеих группах составил 4,4 [3, 4; 5, 4] и 4,7 [3, 4; 5, 5] мм рт. ст. соответственно.
Таблица 6. Эхокардиографические параметры у пациентов после протезирования митрального клапана в зависимости от модели протеза в отдаленном периоде
Table 6. Echocardiographic parameters in patients after mitral valve replacement depending on the prosthesis model in the long-term period
Параметр | МедИнж-СТ | МедИнж-2 | р |
КДО, мл | 121 [101; 127] | 115 [98; 143] | 0,728 |
КСО, мл | 42 [38; 53] | 43 [35; 52] | 0,960 |
КДР, см | 0,857 | ||
КСР, см | 0,983 | ||
ФВ, % | 64 [60; 69] | 63 [59; 66] | 0,846 |
ЛП, см | 0,986 | ||
пикТМГД, мм рт. ст. | 0,581 | ||
срТМГД, мм рт. ст. | 0,425 | ||
Степень регургитации | 0,389 | ||
ПЖ, см | 0,873 | ||
Р ЛА, мм рт. ст. | 34 [26; 43] | 34 [28; 42] | 0,716 |
Обсуждение
В современной литературе данные о частоте послеоперационных осложнений у пациентов, перенесших протезирование митрального клапана отечественным двустворчатым протезом «МедИнж-2», сопоставимы с результатами зарубежных исследований по изучению иностранных моделей клапанов [1, 5, 6]. В настоящее время отсутствуют данные о динамике структурно- геометрических и функциональных параметров сердца после имплантации протеза «МедИнж-СТ» в митральную позицию. В настоящем исследовании мы оценили ранние и отдаленные эхокардиографические показатели сердца после хирургического лечения митральных пороков протезами «МедИнж».
Выбор модели протеза не влиял на показатель госпитальной летальности: в группе полнопроточных протезов – 3,6%, в группе классических протезов – 8,2%. Согласно изученной литературе, показатели летальности в исследуемых группах существенно не отличались от показателей после митрального протезирования другими моделями клапанов [1, 4, 5, 7].
Анализ структурно-функциональных параметров сердца перед выпиской из стационара подтвердил эффективность оперативного лечения в обеих группах. У всех пациентов с преобладанием митрального стеноза наблюдалось значимое снижение величины пикового и среднего ТМГД, систолического давления в легочной артерии. У пациентов с преобладанием митральной недостаточности после операции зарегистрировано значимое уменьшение КДО, КСР, КДР левого желудочка, размеров левого предсердия, Р ЛА и степени регургитации. Динамика данных показателей не зависела от выбранной модели протеза и была сопоставима с показателями после имплантации других моделей клапанов [1, 4, 7]. У всех исследуемых к моменту выписки нарушений функции протеза зарегистрировано не было.
Среди пациентов, перенесших коррекцию порока полнопроточными клапанами, к моменту выписки при эхокардиографическом исследовании выявлено достоверное снижение размеров правого желудочка и степени регургитации в случаях преобладания митрального стеноза, а также значимое уменьшение КСР левого желудочка в случаях преобладания митральной недостаточности. Выявленная динамика параметров сердца свидетельствует о благоприятном влиянии полнопроточных протезов на обратное ремоделирование сердца, чего не было выявлено среди пациентов после протезирования классическими клапанами «МедИнж-2».
Данные эхокардиографических исследований пациентов обеих групп в отдаленном послеоперационном периоде подтвердили положительную динамику структурно-геометрических параметров сердца. Величина пикового и среднего ТМГД была в пределах допустимых значений: 4,4 [3, 4; 5, 4] (группа 1) и 4,7 [3, 4; 5, 5] мм рт. ст. (группа 2). Нарушений функции протезов не выявлено. Значимых различий структурно-функциональных параметров сердца и функциональных характеристик клапанов в зависимости от модели протеза не получено. Отдаленные послеоперационные результаты были сопоставимы с показателями после оперативного лечения другими моделями клапанов [4–8], что подтверждает эффективность данных протезов при коррекции митральных пороков.
Заключение
Анализ структурно-функциональных параметров сердца в послеоперационном периоде показал, что полнопроточный клапан «МедИнж-СТ» в большей степени влияет на обратное ремоделирование правого желудочка и отвечает современным требованиям эффективности и безопасности. Функциональные характеристики клапанов обеих моделей (средний и пиковый ТМГД) оказались сопоставимыми.
В группе пациентов, перенесших протезирование полнопроточным клапаном, не было случаев тромбоза протеза ни в раннем, ни в отдаленном периоде. Таким образом, клапан «МедИнж-СТ» подтвердил свою эффективность при коррекции митральных пороков.
Ограничения исследования. Основными ограничениями исследования являются отсутствие рандомизации при разделении на группы и объем выборки.
Раскрытие интересов. Авторы декларируют отсутствие явных и потенциальных конфликтов интересов, связанных с публикацией настоящей статьи.
Disclosure of interest. The authors declare that they have no competing interests.
Вклад авторов. Авторы декларируют соответствие своего авторства международным критериям ICMJE. Все авторы в равной степени участвовали в подготовке публикации: разработка концепции статьи, получение и анализ фактических данных, написание и редактирование текста статьи, проверка и утверждение текста статьи.
Authors’ contribution. The authors declare the compliance of their authorship according to the international ICMJE criteria. All authors made a substantial contribution to the conception of the work, acquisition, analysis, interpretation of data for the work, drafting and revising the work, final approval of the version to be published and agree to be accountable for all aspects of the work.
Источник финансирования. Авторы декларируют отсутствие внешнего финансирования для проведения исследования и публикации статьи.
Funding source. The author declares that there is no external funding for the exploration and analysis work.
About the authors
Veronika S. Perekopskaya
Omsk State Medical University; Regional Clinical Hospital
Email: perekopskaya.vs@yandex.ru
ORCID iD: 0000-0002-6195-9747
cardiologist, Regional Clinical Hospital, Graduate Student
Russian Federation, Omsk; OmskNataliya A. Morova
Omsk State Medical University
Email: nataliya-morova@yandex.ru
ORCID iD: 0000-0003-0003-692X
D. Sci. (Med.), Prof.
Russian Federation, OmskValeriy N. Tsekhanovich
Omsk State Medical University; Regional Clinical Hospital
Author for correspondence.
Email: cvn50omsk@gmail.com
ORCID iD: 0000-0001-8300-1348
D. Sci. (Med.), Prof.
Russian Federation, Omsk; OmskReferences
- Маркова М.М., Тарасов Д.Г., Чернов И.И., и др. Фатальные и клинически значимые осложнения отдаленного периода после протезирования митрального клапана механическими протезами. Клиническая и экспериментальная хирургия. 2018;6(3):70-6 [Markova MM, Tarasov DG, Chernov II, et al. Fatal and moderate-to-severe long-term complications after mitral valve replacement. Clin Experiment Surg. 2018;6(3):70-6 (in Russian)]. doi: 10.24411/2308-1198-2018-13007
- Иванов В.А., Евсеев Е.П., Айдамиров Я.А., и др. Эволюция протезирования митрального клапана. Хирургия. Журнал им. Н.И. Пирогова. 2018;7:23-8 [Ivanov VA, Evseev EP, Aidamirov YaA, et al. Evolution of mitral valve replacement. Khirurgiya. Zhurnal im. N.I. Pirogova. 2018;7:23-8 (in Russian)]. doi: 10.17116/hirurgia2018723
- Кузьмина О.К., Рутковская Н.В. Ремоделирование миокарда при поражениях клапанов сердца. Сибирское медицинское обозрение. 2017;104(2):5-14 [Kuz'mina OK, Rutkovskaya NV. Myocardium remodeling in the heart valves disorders. Sibirskoe medicinskoe obozrenie. 2017;104(2):5-14 (in Russian)]. doi: 10.20333/2500136-2017-2-5-14
- Абдульянов И.В., Вагизов И.И., Каипов А.Э. Клинические результаты протезирования клапанов сердца двустворчатым полнопроточным механическим протезом «МедИнж-СТ». Ангиология и сосудистая хирургия. 2020;26(4):141-8 [Abdul'yanov IV, Vagizov II, Kaipov AE. Clinical results of prosthetics of heart valves with a bivalve full-flow mechanical prosthesis «MedInzh-ST». Angiology and vascular surgery. 2020;26(4):141-8 (in Russian)]. doi: 10.33529/ANGIO2020419
- Coutinho GF, Correia PM, Branco C, et al. Long-term results of mitral valve surgery for degenerative anterior leaflet or bileaflet prolapse: analysis of negative factors for repair, early and late failures, and survival. Eur J Cardiothorac Surg. 2016;50(1):66-74. doi: 10.15761/CDM.1000153
- Пукас Е.В., Лазоришинец В.В. Отдаленные результаты протезирования митрального клапана. Украинский журнал сердечно- сосудистой хирургии. 2018;10:44-7 [Pukas EV, Lazorishinec VV. Long-term results of mitral valve replacement. Ukrainian Journal of Cardiovascular Surgery. 2018;10:44-7 (in Russian)]. doi: 10.30702/ujcvs/18.32/10(044-047)
- Мартьянова Ю.Б., Кондратьев Д.А., Маркова М.М., и др. Непосредственные результаты хирургического лечения дисплазий митрального клапана. Клиническая и экспериментальная хирургия. 2019;7(1):28-33. [Mart'yanova YuB, Kondrat'ev DA, Markova MM, et al. Fatal and moderate-to-severe long-term complications after mitral valve replacement. Clinical and Experimental Surgery. 2019;7(1):28-33 (in Russian)]. doi: 10.24411/2308-1198-2019-11004
- Ивлева О.В., Авдеева М.В. Влияние протезирования митрального клапана на функциональную перестройку сердца у больных с синусовым ритмом и фибрилляцией предсердий. Креативная кардиология. 2018;12(1):40-9 [Ivleva OV, Avdeeva MV. Functional heart restoration after mitral valve replacement in patients with sinus rhythm and atrial fibrillationj. Creative Cardiology. 2018;12(1):40-9 (in Russian)]. doi: 10.24022/1997-3187-2018-12-1-40-49
Supplementary files
There are no supplementary files to display.
